- 封装:24-SSOP(0.209",5.30mm 宽)
- RoHS:含铅 / 不受限制有害物质指令(RoHS)规范要求限制
- 包装方式:管件
- 参考价格:$1-$2.48
更新日期:2024-04-01
产品简介:1.2mA/1.2mA 4 通道栅极驱动器,可在负载短路、负载开路和电池过压时执行禁用操作
查看详情- 封装:24-SSOP(0.209",5.30mm 宽)
- RoHS:含铅 / 不受限制有害物质指令(RoHS)规范要求限制
- 包装方式:管件
- 参考价格:$1-$2.48
TPIC44L01DB 供应商
- 公司
- 型号
- 品牌
- 封装/批号
- 数量
- 地区
- 日期
- 说明
- 询价
-
TI
-
原厂原装
22+ -
3288
-
上海市
-
-
-
一级代理原装
-
-
2019+ -
5800
-
上海市
-
-
-
全新原装现货
-
TI
-
SSOP
21+ -
3000
-
上海市
-
-
-
原装现货,品质为先!请来电垂询!
-
TI
-
SSOP24
21+ -
28000
-
上海市
-
-
-
原装进口
-
TI/德州仪器
-
21+
SSOP24 -
10000
-
杭州
-
-
-
只做原装现货,大量现货热卖
TPIC44L01DB 中文资料属性参数
- 标准包装:60
- 类别:集成电路 (IC)
- 家庭:PMIC - MOSFET,电桥驱动器 - 外部开关
- 系列:-
- 配置:低端
- 输入类型:非反相
- 延迟时间:4µs
- 电流 - 峰:1.2mA
- 配置数:4
- 输出数:4
- 高端电压 - 最大(自引导启动):-
- 电源电压:4.5 V ~ 5.5 V
- 工作温度:-40°C ~ 125°C
- 安装类型:表面贴装
- 封装/外壳:24-SSOP(0.209",5.30mm 宽)
- 供应商设备封装:24-SSOP
- 包装:管件
- 其它名称:296-10867-5
产品特性
- 4-Channel Serial-In Parallel-In Low-Side Pre-FET Driver
- Devices Are Cascadable
- Internal 55-V Inductive Load Clamp and VGS Protection Clamp for External Power FETs
- Independent Shorted-Load/Short-to-Battery Fault Detection on All Drain Terminals
- Independent OFF-State Open-Load Fault Sense
- Over-Battery-Voltage Lockout Protection and Fault Reporting
- Under-Battery Voltage Lockout Protection for the TPIC44L01 and TPIC44L02
- Asynchronous Open-Drain Fault Flag
- Device Output Can Be Wire-ORed With Multiple Devices
- Fault Status Returned Through Serial Output Terminal
- Internal Global Power-On Reset of Device and External RESET Terminal
- High-Impedance CMOS-Compatible Inputs With Hysteresis
- TPIC44L01 and TPIC44L03 Disables the Gate Output When a Shorted-Load Fault Occurs
- TPIC44L02 Transitions the Gate Output to a Low-Duty Cycle PWM Mode When a Shorted-Load Fault Occurs
产品概述
The TPIC44L01, TPIC44L02, and TPIC44L03 are low-side predrivers that provide serial and parallel
input interfaces to control four external FET power switches such as offered in the TI TPIC family of
power arrays. These devices are designed primarily for low-frequency switching, inductive
load applications such as solenoids and relays. Fault status for each channel is available in a
serial-data format. Each driver channel has independent off-state open-load detection and
on-state shorted-load/short-to-battery detection. Battery overvoltage and undervoltage detection
and shutdown is provided on the TPIC44L01/L02. On the TPIC44L03 driver, only over-battery
voltage shutdown is provided. Each channel also provides inductive-voltage-transient protection
for the external FET.
These devices provide control of output channels through a serial input interface or a parallel input interface.
A command to enable the output from either interface enables the respective channels gate output to the
external FET. The serial interface is recommended when the number of signals between the control device and
the predriver must be minimized and the speed of operation is not critical. In applications where the predriver
must respond very quickly or asynchronously, the parallel input interface is recommended.
For serial operation, the control device must transition CS\ from high to low to activate the serial input interface.
When this occurs, SDO is enabled, fault data is latched into the serial interface, and the fault flag is refreshed.
Data is clocked into the serial registers on low-to-high transitions of SCLK through SDI. Each string of data must
consist of at least four bits of data. In applications where multiple devices are cascaded together, the string of
data must consist of four bits for each device. A high data bit turns the respective output channel on and a low
data bit turns it off. Fault data for the device is clocked out of SDO as serial input data is clocked into the device.
Fault data consists of fault flags for shorted-load and open-load flags (bits 0\x963) for each of the four output
channels. A high bit in the fault data indicates a fault and a low bit indicates that no fault is present for that
channel. Fault register bits are set or cleared asynchronously to reflect the current state of the hardware. A fault
must be present when CS\ is transitioned from high to low to be captured and reported in the serial fault data.
New faults cannot be captured in the serial register when CS\ is low. CS\ must be transitioned high after all of
the serial data has been clocked into the device. A low-to-high transition of CS\ transfers the last four bits of serial
data to the output buffer puts SDO in a high-impedance state and clears and reenables the fault register. The
TPIC44L01/L02/L03 was designed to allow the serial input interfaces of multiple devices to be cascaded
together to simplify the serial interface to the controller. Serial input data flows through the device and is
transferred out SDO following the fault data in cascaded configurations.
For parallel operation, data is transferred directly from the parallel input interface IN0-IN3 to the respective
GATE(0\x963) output asynchronously. SCLK or CS\ is not required for parallel control. A 1 on the parallel input turns
the respective channel on, where a 0 turns it off. Note that either the serial input interface or the parallel input
interface can enable a channel. Under parallel operation, fault data must still be collected through the serial data
interface.
The predrivers monitor the drain voltage for each channel to detect shorted-load or open-load fault conditions
in the the on and off states respectively. These devices offer the option of using an internally generated
fault-reference voltage or an externally supplied fault-reference voltage through VCOMP for fault detection. The
internal fault reference is selected by connecting VCOMPEN to GND and the external reference is selected by
connecting VCOMPEN to VCC. The drain voltage is compared to the fault reference when the channel is turned
on to detect shorted-load conditions and when the channel is off to detect open-load conditions. When a shorted
fault occurs using the TPIC44L01 or the TPIC44L03, the channel is turned off and a fault flag is sent to the control
device as well as to the serial fault register bits. If a fault occurs while using the TPIC44L02, the channel
transitions into a low-duty cycle, pulse-width-modulated (PWM) signal as long as the fault is present.
Shorted-load fault conditions must be present for at least the shorted-load deglitch time, t(STBDG), to be flagged
as a fault. A fault flag is sent to the control device as well as the serial fault register bits. More detail on fault
detection operation is presented in the device operation section of this data sheet.
These devices provide protection from over-battery voltage and under-battery voltage conditions irrespective
of the state of the output channels. When the battery voltage is greater than the overvoltage threshold or less
than the undervoltage threshold, all channels are disabled and a fault flag is generated. Battery-voltage faults
are not reported in the serial fault data. The outputs return to normal operation once the battery-voltage fault
has been corrected. When an over-battery/under-battery voltage condition occurs, the device reports the
battery fault, but disables fault reporting for open- and shorted-load conditions. Fault reporting for open- and
shorted-load conditions are reenabled after the battery fault condition has been corrected.
These devices provide inductive transient protection on all channels. The drain voltage is clamped to protect
the FET. The clamp voltage is defined by the sum of VCC and turnon voltage of the external FET. The predriver
also provides a gate-to-source voltage (VGS) clamp to protect the gate-source terminals of the power FET from
exceeding their rated voltages. An external active low RESET\ is provided to clear all registers and flags in the
device. GATE(0\x963) outputs are disabled after RESET\ has been pulled low.
These devices provide pulldown resistors on all inputs except CS\ and RESET\. A pullup resistor is used on CS\
and RESET\.
TPIC44L01DB 数据手册
数据手册 | 说明 | 数量 | 操作 |
---|---|---|---|
![]() |
4-CHANNEL SERIAL AND PARALLEL LOW-SIDE PRE-FET DRIVER |
20 Pages页,269K | 查看 |
TPIC44L01DB 相关产品
- 2ED020I12-F
- 2ED020I12-FI
- A3985SLDTR-T
- A4935KJPTR-T
- ADP3110AKCPZ-RL
- ADP3110AKRZ-RL
- ADP3118JRZ-RL
- ADP3120AJCPZ-RL
- ADP3120AJRZ
- ADP3120AJRZ-RL
- ADP3412JR
- ADP3419JRMZ-REEL
- ADP3623ARDZ-RL
- ADP3624ARHZ-RL
- ADP3625ARDZ-RL
- ADP3629ARZ-R7
- ADP3630ARZ-R7
- ADP3631ARZ-R7
- ADP3654ARHZ
- ADP3654ARHZ-R7
- ADUM7234BRZ
- AUIRS2117STR
- AUIRS21814STR
- CS4161YN8
- FAN3121TMX
- FAN3213TMX
- FAN3223TMX
- FAN3224TMX
- FAN3225TMX
- FAN3226TMX